ZBW Series Combined Substation
+
  • ZBW Series Combined Substation

ZBW Series Combined Substation

The ZBW series combined substation, commonly known as the European‑style pad-mounted substation, integrates high‑voltage switchgear, transformers, and low‑voltage switchgear into a compact, prefabricated distribution unit. It is used in urban high‑rise buildings, rural and urban construction sites, residential communities, high‑tech development zones, small and medium‑sized factories, mines, oilfields, and temporary construction power supply applications, serving to receive and distribute electrical energy within the distribution system.




Product Details


The ZBW series combined substation, commonly known as the European‑style pad-mounted substation, integrates high‑voltage switchgear, transformers, and low‑voltage switchgear into a compact, prefabricated distribution unit. It is used in urban high‑rise buildings, rural and urban construction sites, residential communities, high‑tech development zones, small and medium‑sized factories, mines, oilfields, and temporary construction power supply applications, serving to receive and distribute electrical energy within the distribution system.

The ZBW series modular substations feature high levels of integration, compact dimensions, a streamlined structure, safe and reliable operation, convenient maintenance, and portability. Compared with conventional civil‑engineered substations, a modular substation of the same capacity typically occupies only 1/10 to 1/5 of the footprint of a conventional substation, significantly reducing design and construction effort and lowering capital costs. In distribution applications, these units can be deployed in ring‑network distribution systems as well as in dual‑source or radial terminal distribution networks, making them a cutting‑edge, prefabricated solution for the construction and upgrading of substations in both urban and rural areas.

The ZBW series modular substations comply with the standards specified in SD 320-1992, “Technical Conditions for Box-Type Substations,” and GB/T 17467-1997, “High-Voltage/Low-Voltage Prefabricated Substations.”

 

Working conditions

Altitude not exceeding 1000 m;

The ambient temperature shall not exceed +40°C, nor fall below -25°C, and the 24-hour average temperature shall not exceed +35°C.

Outdoor wind speed does not exceed 35 m/s;

The air‑to‑surface temperature shall not exceed 90% (+25°C);

The horizontal seismic acceleration shall not exceed 0.4 m/s², and the vertical seismic acceleration shall not exceed 0.2 m/s².

Locations free from fire hazards, explosion risks, severe contamination, chemical corrosion, and intense vibrations.

Special usage conditions shall be resolved through consultation with our company at the time of order placement.

 

Main Technical Parameters

Serial number

Project

Unit

High-voltage electrical apparatus

Transformer

Low-voltage electrical appliances

1

Rated voltage Ue

kV

7.2, 12

6/0.4, 10/0.4

0.4

2

Rated capacity Se

kVA

 

Eye type: 200~1250

 

 

3

Rated current Le

kVA

200~630

 

100~3000

4

Rated breaking current

A

kA

Load switch 400~630A

The combination electrical apparatus depends on the fuse.

 

15~63

5

Rated short-time

Withstand current

kA

20 (2S)

12.5 (4S)

200~400 kVA

15 (1S)

400kVA

30 (1S)

6

Rated peak value

Withstand current

kA

31.5, 50

200~400 kVA

30

400kVA

63

7

Rated making current

kA

31.5, 50

 

 

8

Power-frequency withstand voltage

Voltage 1 min

kX

Relative and interphase 42, 30

Isolation break 48, 34

Oil change: 35/5 min

2 kV at ≤300 V

Dry-type transformer 28/5 min

At 300,660 V

2.5kV

9

Lightning Impulse

kV

Relative and interphase 75.60

Isolation break 85, 75

75

 

10

Noise level

dB

 

Oil change: <55

 

Dry-type transformer <65

11

Protection rating

 

IP33

IP23

IP33

12

External dimensions

Select different external dimensions based on the chosen transformer capacity and type.

 

1. This product is assembled by connecting a high-voltage switchgear, a transformer, and a low-voltage switchgear, and is divided into three functional compartments: the high-voltage compartment, the transformer compartment, and the low-voltage compartment. Both the high- and low-voltage compartments are fully equipped; the high-voltage side can accommodate various power supply configurations, including ring‑network supply, terminal supply, and dual‑source supply, and may also be fitted with high‑voltage metering equipment to meet high‑voltage metering requirements. The transformer compartment offers a choice of S9 and S11 series low‑loss oil‑immersed transformers, as well as SC(B)9, SCR9, SC(B)10, and SCR10 series dry‑type transformers. It is equipped with an automatically activated forced‑air cooling system and an illumination system. The low-voltage compartment, configured according to user requirements in either panel‑type or cabinet‑type structures, provides tailored power distribution solutions that include power distribution, lighting distribution, reactive power compensation, electrical energy metering, and electricity consumption measurement, thereby meeting diverse user needs while facilitating convenient power management and enhancing power supply quality.

2. The high-voltage compartment features a compact, well‑organized structure and is equipped with comprehensive “five‑prevention” interlocking functions to prevent erroneous operations. Upon customer request, the transformer may be fitted with rails that allow convenient access through the side doors of the front transformer compartment. Each compartment is provided with automatic lighting, and all components selected for both the high- and low-voltage compartments are highly reliable and easy to operate, ensuring safe and dependable operation as well as convenient maintenance.

3. Both natural ventilation and forced ventilation are employed to ensure effective cooling. The transformer room and the low-voltage room are equipped with ventilation ducts, and the exhaust fans are fitted with temperature‑controlled devices that automatically start and stop according to the set temperature, thereby ensuring the transformer can operate at full load.

4. The enclosure structure is designed to prevent the ingress of rainwater and contaminants, constructed from specialized steel or aluminum alloy panels and treated with anti-corrosion coatings, ensuring suitability for long-term outdoor use. It delivers robust corrosion resistance, waterproofing, and dustproofing, boasts an extended service life, and maintains an aesthetically pleasing appearance.

Tags:

ZBW Series Combined Substation

Product Inquiry

If you are interested in our services, please fill out the form below and we will contact you as soon as possible.