220 kV three-phase oil-immersed on-load tap-changing power transformer
+
  • 220 kV three-phase oil-immersed on-load tap-changing power transformer

220 kV three-phase oil-immersed on-load tap-changing power transformer

The 220 kV three-phase oil-immersed on-load tap-changing power transformer incorporates a series of major innovations in materials, manufacturing processes, and structural design. It features a compact footprint, light weight, high efficiency, low losses, reduced noise, and reliable operation, thereby significantly cutting grid losses and operating costs and delivering substantial economic benefits. It is suitable for use in power plants, substations, and large industrial and mining enterprises.




Product Details


The 220 kV three-phase oil-immersed on-load tap-changing power transformer incorporates a series of major innovations in materials, manufacturing processes, and structural design. It features a compact footprint, light weight, high efficiency, low losses, reduced noise, and reliable operation, thereby significantly cutting grid losses and operating costs and delivering substantial economic benefits. It is suitable for use in power plants, substations, and large industrial and mining enterprises.

This product complies with the following national standards: GB 1094.1-2013 “Power Transformers — Part 1: General Requirements,” GB 1094.2-2013 “Power Transformers — Part 2: Temperature Rise,” GB 1094.3-2003 “Power Transformers — Part 3: Insulation Levels, Insulation Tests, and External Insulation Air Gaps,” GB 1094.5-2003 “Power Transformers — Part 5: Short‑Circuit Withstand Capability,” and GB/T 6451-2015 “Technical Parameters and Requirements for Three‑Phase Oil‑Immersed Power Transformers.”

 

Operating environmental conditions

1. Device Type: Outdoor Type

2. Ambient temperature: maximum +40°C, minimum -30°C

3. Altitude: ≤1000 m (for altitudes >1000 m, temperature rise must be corrected)

4. Relative humidity: ≤90% (25°C)

5. Installation location: Areas free of corrosive gases and significant dirt or contamination.

 

Technical Specifications

31,500 kVA to 180,000 kVA three-phase, double-winding, on-load tap-changing power transformer

Rated capacity

(kVA)

Voltage combinations and tap ranges

Connection Group

No-load loss

kW (9)

Load loss

kW (9)

No-load current

%

Short-circuit impedance

%

High voltage kV

Low-voltage kV

31500

220±8×1.25%

230±8×1.25%

6.3, 6.6

10.5, 21

36, 37

38.5

YNd11

30.0

128

0.57

12~14

40000

36.0

149

0.57

50000

43.0

179

0.53

63000

50.0

209

0.53

90000

64.0

273

0.45

120000

10.5, 21, 36, 37, 38.5

79.0

338

0.45

150000

92.0

400

0.41

180000

108

459

0.38

120000

81.0

337

0.45

150000

66

69

96.0

394

0.41

180000

112

451

0.38

240000

140

560

0.30

Note 1: Low-voltage transformers rated at 35 kV are also available upon request.