35kV Three-Phase Oil-Immersed On-Load Tap-Changing Power Transformer
+
  • 35kV Three-Phase Oil-Immersed On-Load Tap-Changing Power Transformer

35kV Three-Phase Oil-Immersed On-Load Tap-Changing Power Transformer

The SZ11 series 35 kV on‑load tap‑changing power transformer is a high‑voltage oil‑immersed transformer specifically designed for transmission and distribution in 35 kV networks. Featuring an on‑load tap‑changing capability of ±3 × 2.5%, it enables continuous voltage regulation without interrupting power supply, making it particularly well suited for substations and power systems that demand high output voltage stability under varying load conditions.




Product Details


The 35 kV three-phase oil-immersed on-load tap-changing power transformer incorporates a series of major innovations in materials, manufacturing processes, and structural design. It features a compact footprint, light weight, high efficiency, low losses, reduced noise, and reliable operation, thereby significantly cutting grid losses and operating costs and delivering substantial economic benefits. It is suitable for use in power plants, substations, large industrial and mining enterprises, and similar applications.

This product complies with the following national standards: GB 1094.1-2013 “Power Transformers — Part 1: General Requirements,” GB 1094.2-2013 “Power Transformers — Part 2: Temperature Rise,” GB 1094.3-2003 “Power Transformers — Part 3: Insulation Levels, Insulation Tests, and External Insulation Air Gaps,” GB 1094.5-2003 “Power Transformers — Part 5: Short‑Circuit Withstand Capability,” and GB/T 6451-2015 “Three‑Phase Oil‑Immersed Power Transformers — Technical Parameters and Requirements.”

 

Operating environmental conditions

1. Device Type: Outdoor Type

2. Ambient temperature: maximum +40°C, minimum -30°C

3. Altitude: ≤1000 m (for altitudes >1000 m, temperature rise must be corrected)

4. Relative humidity: ≤90% (25°C)

 

5. Installation location: Areas free of corrosive gases and significant dirt or contamination.
 

Technical Specifications

2000 kVA to 31,500 kVA three-phase, double-winding, on-load tap-changing power transformer

Rated capacity

(kVA)

Voltage combinations and tap ranges

Connection Group

No-load loss

kW (9)

Load loss

kW (9)

No-load current

%

Short-circuit impedance

%

High voltage kV

High-voltage tap range

Low-voltage kV

2000

35

±3×2.5%

6.3

10.5

Yd11

2.30

19.2

0.50

6.5

2500

2.72

20.6

0.50

3150

35~38.5

3.23

24.7

0.50

7.0

4000

3.87

29.1

0.50

5000

4.64

34.2

0.50

6300

5.63

36.7

0.50

8000

35~38.5

6.3

6.6

10.5

YNd11

7.87

40.6

0.40

8.0

10000

9.28

48.0

0.40

12500

10.9

56.8

0.35

16000

13.1

70.3

0.35

20000

15.5

82.7

0.30

25000

18.3

97.8

0.30

10.0

315000

21.8

116

0.30

Note:

1. Upon customer request, products with capacities not listed in the table can be manufactured, with performance parameters determined according to specific requirements.

2. Depending on the operating environment, we can provide specially designed products.

3. For medium voltage, options include voltages different from those listed in the table or tap settings; for high voltage, asymmetric tap‑changing is selected.

4. The short-circuit impedance may be selected to differ from the values listed in the table.

5. The final dimensions shall be subject to the drawing confirmation following contract signing.

 

Structural features

Tags:

35kV Three-Phase Oil-Immersed On-Load Tap-Changing Power Transformer

Product Inquiry

If you are interested in our services, please fill out the form below and we will contact you as soon as possible.