SG(B)10-100-2500/10 Series H-Class Insulated Three-Phase Dry-Type Transformer
+
  • SG(B)10-100-2500/10 Series H-Class Insulated Three-Phase Dry-Type Transformer

SG(B)10-100-2500/10 Series H-Class Insulated Three-Phase Dry-Type Transformer

This product series comprises high‑performance, highly secure, and environmentally friendly dry‑type transformers independently developed by our company based on German MORA technology. They are particularly well suited for applications with stringent fire‑safety requirements, significant load fluctuations, and harsh, humid, and dusty environments—such as airports, power plants, metallurgical facilities, hospitals, high‑rise buildings, shopping centers, and densely populated areas. They are also widely deployed in specialized settings, including petrochemical plants, nuclear power stations, and nuclear submarines.




Product Details


This product series comprises high‑performance, highly secure, environmentally friendly dry‑type transformers independently developed by our company based on German MORA technology. They are particularly well suited for applications with stringent fire‑safety requirements, significant load fluctuations, and harsh, humid, dust‑prone environments—such as airports, power plants, metallurgical facilities, hospitals, high‑rise buildings, shopping centers, and densely populated areas. They are also widely deployed in specialized settings, including petrochemical plants, nuclear power stations, and nuclear submarines.

Implementation Standard

1. GB 1094.11-2007 Dry-Type Power Transformers.

2. GB/T 10228-2015 Technical Parameters and Requirements for Dry-Type Power Transformers.

3. GB/T 17211-1998 Guidelines for the Load Operation of Dry-Type Power Transformers.

4. GB 10237-1998 Insulation Levels and Insulation Tests for Power Transformers.

5. GB 4028-1993 Degrees of Protection Provided by Enclosures (IP Code).

6. JB/T 10008-1998 Acoustic Noise Levels of Transformers Rated 6–220 kV.

7. JB/T 56009-1998 Quality Grades for Dry-Type Power Transformers.

 

Performance Characteristics

1. Excellent heat dissipation, long service life, and high load-bearing capacity; under continuous full-load operation, no forced air cooling is required, with an ingress protection rating of IP45, enabling prolonged full-load operation.

2. It boasts exceptionally high safety and flame-retardant properties, producing no smoke even when subjected to prolonged combustion at 800°C.

3. Excellent thermal shock resistance (capable of immediate full-load start-up at −50°C).

4. 100% waterproof seal, excellent hydrophobic performance, and outstanding moisture resistance.

5. The unique coil structure and advanced field calculations ensure that this product virtually eliminates partial discharge.

6. Low losses and significant energy savings: Compared with the SC9 series dry-type transformers, no-load losses are reduced by an average of 10%, and load losses are reduced by 5%.

7. At the end of its service life, the insulating material can be easily separated from the copper conductors and recycled without causing environmental pollution.

 

Main Technical Parameters

SG(B)10-100-2500/10 Series H-Class Insulated Three-Phase Dry-Type Power Transformer
Transformer Technical Parameters

Rated Capacity (kVA)

Voltage combination

No-load loss (W)

Load loss

(W)

No-load current (%)

Short-circuit impedance (%)

Weight (kg)

Track gauge A×B (mm)

External dimensions (mm): Length × Width × Height

Overall dimensions (mm): Length × Width × Height

High voltage (kV)

Decomposition Scope

Low
Pressure

(kV)

Connection Group

100

6,6.3;
6.6;
10;
10.5;
11;

±5%
Or
±2x
2.5%;

0.4

Yyn0
Or
Dyn11

480

1880

 

4

700

660x400

980x500x920

1340x900x1150

160

560

2700

750

660x400

1020x500x960

1400x900x1200

200

620

3100

880

660x400

1050x500x1150

1450x900x1400

250

760

3850

2.0

1050

660x400

1090x500x1310

1450x900x1550

315

880

4600

1380

660x660

1240x770x1355

1600x1100x1600

400

1040

5400

1.8

1750

820x820

1310x960x1390

1700x1100x1650

500

1200

6600

1880

820x820

1370x630x1400

1750x1100x1700

630

1340

8050

1.4

6

1950

820x820

1400x960x1445

1800x1250x1750

800

1690

9500

2200

820x820

1470x960x1495

1850x1250x1800

1000

1980

11400

1.2

2490

820x820

1510x960x1505

1900x1250x1800

1250

2380

12500

3050

1070x1070

1620x1255x1585

2000x1300x1850

1600

2730

14900

3690

1070x1070

1660x1588x1675

2050x1300x2000

2000

3320

17500

1.0

4400

1070x 1070

1730x1255x1840

2100x1350x2150

2500

4000

20300

4940

1070x1070

1780x1288x1930

2150x1350x2200

 