SG(B)10-100-2500/10 Series H-Class Insulated Three-Phase Dry-Type Transformer
This product series comprises high‑performance, highly secure, and environmentally friendly dry‑type transformers independently developed by our company based on German MORA technology. They are particularly well suited for applications with stringent fire‑safety requirements, significant load fluctuations, and harsh, humid, and dusty environments—such as airports, power plants, metallurgical facilities, hospitals, high‑rise buildings, shopping centers, and densely populated areas. They are also widely deployed in specialized settings, including petrochemical plants, nuclear power stations, and nuclear submarines.
Category:
Product Details
This product series comprises high‑performance, highly secure, environmentally friendly dry‑type transformers independently developed by our company based on German MORA technology. They are particularly well suited for applications with stringent fire‑safety requirements, significant load fluctuations, and harsh, humid, dust‑prone environments—such as airports, power plants, metallurgical facilities, hospitals, high‑rise buildings, shopping centers, and densely populated areas. They are also widely deployed in specialized settings, including petrochemical plants, nuclear power stations, and nuclear submarines.
Implementation Standard
1. GB 1094.11-2007 Dry-Type Power Transformers.
2. GB/T 10228-2015 Technical Parameters and Requirements for Dry-Type Power Transformers.
3. GB/T 17211-1998 Guidelines for the Load Operation of Dry-Type Power Transformers.
4. GB 10237-1998 Insulation Levels and Insulation Tests for Power Transformers.
5. GB 4028-1993 Degrees of Protection Provided by Enclosures (IP Code).
6. JB/T 10008-1998 Acoustic Noise Levels of Transformers Rated 6–220 kV.
7. JB/T 56009-1998 Quality Grades for Dry-Type Power Transformers.
Performance Characteristics
1. Excellent heat dissipation, long service life, and high load-bearing capacity; under continuous full-load operation, no forced air cooling is required, with an ingress protection rating of IP45, enabling prolonged full-load operation.
2. It boasts exceptionally high safety and flame-retardant properties, producing no smoke even when subjected to prolonged combustion at 800°C.
3. Excellent thermal shock resistance (capable of immediate full-load start-up at −50°C).
4. 100% waterproof seal, excellent hydrophobic performance, and outstanding moisture resistance.
5. The unique coil structure and advanced field calculations ensure that this product virtually eliminates partial discharge.
6. Low losses and significant energy savings: Compared with the SC9 series dry-type transformers, no-load losses are reduced by an average of 10%, and load losses are reduced by 5%.
7. At the end of its service life, the insulating material can be easily separated from the copper conductors and recycled without causing environmental pollution.
Main Technical Parameters
SG(B)10-100-2500/10 Series H-Class Insulated Three-Phase Dry-Type Power Transformer
Transformer Technical Parameters
Rated Capacity (kVA) |
Voltage combination |
No-load loss (W) |
Load loss (W) |
No-load current (%) |
Short-circuit impedance (%) |
Weight (kg) |
Track gauge A×B (mm) |
External dimensions (mm): Length × Width × Height |
Overall dimensions (mm): Length × Width × Height |
|||
High voltage (kV) |
Decomposition Scope |
Low (kV) |
Connection Group |
|||||||||
100 |
6,6.3; |
±5% |
0.4 |
Yyn0 |
480 |
1880 |
|
4 |
700 |
660x400 |
980x500x920 |
1340x900x1150 |
160 |
560 |
2700 |
750 |
660x400 |
1020x500x960 |
1400x900x1200 |
||||||
200 |
620 |
3100 |
880 |
660x400 |
1050x500x1150 |
1450x900x1400 |
||||||
250 |
760 |
3850 |
2.0 |
1050 |
660x400 |
1090x500x1310 |
1450x900x1550 |
|||||
315 |
880 |
4600 |
1380 |
660x660 |
1240x770x1355 |
1600x1100x1600 |
||||||
400 |
1040 |
5400 |
1.8 |
1750 |
820x820 |
1310x960x1390 |
1700x1100x1650 |
|||||
500 |
1200 |
6600 |
1880 |
820x820 |
1370x630x1400 |
1750x1100x1700 |
||||||
630 |
1340 |
8050 |
1.4 |
6 |
1950 |
820x820 |
1400x960x1445 |
1800x1250x1750 |
||||
800 |
1690 |
9500 |
2200 |
820x820 |
1470x960x1495 |
1850x1250x1800 |
||||||
1000 |
1980 |
11400 |
1.2 |
2490 |
820x820 |
1510x960x1505 |
1900x1250x1800 |
|||||
1250 |
2380 |
12500 |
3050 |
1070x1070 |
1620x1255x1585 |
2000x1300x1850 |
||||||
1600 |
2730 |
14900 |
3690 |
1070x1070 |
1660x1588x1675 |
2050x1300x2000 |
||||||
2000 |
3320 |
17500 |
1.0 |
4400 |
1070x 1070 |
1730x1255x1840 |
2100x1350x2150 |
|||||
2500 |
4000 |
20300 |
4940 |
1070x1070 |
1780x1288x1930 |
2150x1350x2200 |
||||||