Welcome to Jiangxi People Transmit & Transform Electric Co.,Ltd Official website!
Structural characteristics and classification of dry-type transformers
Published Time:
2026-06-24
A temperature display controller can be installed on the epoxy resin dry-type transformer to display and control the operating temperature of the transformer winding, ensuring the normal service life of the transformer.
Structural characteristics of dry-type transformers
1. All high and low voltage windings are wound with copper strips (foils);
2. The high and low voltage windings are all cast with epoxy resin in vacuum and cured to form a high-strength fiberglass structure;
3. The high and low voltage windings are equipped with longitudinal ventilation ducts according to heat dissipation requirements;
4. The inner and outer surfaces of the coil are covered with fiberglass mesh cloth;
5. The insulation level includes F and H levels;
6. Epoxy resin dry-type transformers have small volume and light weight.
Classification of dry-type transformers
A temperature display controller can be installed on the epoxy resin dry-type transformer to display and control the operating temperature of the transformer winding, ensuring the normal service life of the transformer. The temperature sensor PT100 platinum resistor is inserted into the low-voltage winding to obtain temperature signals. After circuit processing, the temperature of each phase winding is cyclically displayed on the control board. It has temperature setting function, manual/automatic start and stop of the fan, sound and light signal alarm for faults and overheating, and automatic tripping for overheating. It has the national anti electromagnetic interference capability. At the same time, intelligent computer interfaces are reserved to achieve remote control. The epoxy resin dry-type transformer is equipped with a low-noise amplitude current fan, which can reduce the winding temperature, improve the load capacity, and extend the transformer life after starting; When using forced air cooling, the rated capacity can be increased by 40-50%.
The superior performance of dry-type transformers is particularly reflected in terms of noise. Noise is an important factor that affects and restricts the development of amorphous alloy dry-type transformers, and it is also a major challenge in the design and manufacturing of this new product. Although the standard JB/T10088 "Sound Level of 6-500kV Power Transformers" does not specify the noise level of amorphous products, the measured sound level of this new product produced by the company is significantly lower than the noise requirements for silicon steel sheet products of the same capacity in the standard, reaching the sound level of oil immersed transformers. The solution to the problem of noise makes it possible to promote the use of amorphous alloy dry-type transformers.
Due to the extremely sensitive nature of amorphous alloy iron cores, their structural characteristics determine that the stress of amorphous alloy dry-type transformers is not as good as traditional transformers due to their strong short-circuit resistance. Therefore, the "ability test to withstand sudden short circuits" has become a bottleneck restricting the production, manufacturing, and sales promotion of amorphous alloy dry-type transformers. The 2000 kVA amorphous alloy prototype developed by the company passed the three-phase sudden short circuit test in one go, successfully solving this problem and demonstrating its technical level.
The innovation of dry-type transformers mainly focuses on energy conservation, environmental protection, and optimization of performance parameters. Especially in the research of global issues such as transformer losses and sound level, China has achieved many gratifying results. However, it is worth noting that it is not entirely reasonable to demand lower loss values for the same raw materials. At this point, the decrease in no-load loss will lead to an increase in the amount of iron (silicon steel sheets) used, and the decrease in load loss will lead to an increase in the amount of copper used. The pros and cons of benefits and expenses need to be carefully weighed and compared.